Calibrators & Controls

There occurred error (s)

    Elisys Duo

    CoreLab DXELISAInstrumentsAnalyzers
    Get a consultation

    2-plate fully automated ELISA analyzer incl. UPSbest solution for the medium throughput segment

    The Elisys Duo is a 2-plate fully automated ELISA analyzer for the medium throughput segment. This sophisticated analyzer includes an uninterruptible power supply (UPS), ensuring uninterrupted operation and making it the ideal solution for labs seeking efficiency and reliability.

    The Elisys Duo expands your testing capabilities by allowing up to 3 plates to be processed simultaneously. It features two independent incubators, facilitating diverse assay requirements with ease. At its core, a built-in PC equipped with user-friendly Windows software and a touch screen interface streamlines operation and data management.

    The Elisys Duo is pre-programmed for most HUMAN and IMTEC ELISA tests, offering flexibility with open protocols for user-defined assays.
    feature icon

    Throughput

    Up to 3 plates per run
    feature icon

    Reading

    Up to 8 different tests on one plate
    feature icon

    8-filter wheel

    Equipped with 450 and 620 nm filters, it guarantees the best wavelength selection for diverse assays.
    feature icon

    Continuous loading

    Enhances operational productivity with continous loading of samples, reagents, and plates
    feature icon

    Plug and run

    Most HUMAN assays preprogrammed and user programmable tests
    feature icon

    Barcode Reader

    Barcode identification for samples and reagents
    feature icon

    UPS (uninterruptible power supply)

    Ensures uninterrupted operation, minimizing the risk of result loss due to power failures
    feature icon

    Integrated PC and touchscreen

    Offers an enhanced user experience with integrated PC and touchscreen
    feature icon

    Incubation

    Features 2 independent incubators, ensuring precise temperature control for optimal assay performance
    feature icon

    LIS

    ASTM interface for bi-directional communication

    High-capacity design for maximum efficiency

    • Large sample handling with up to 144 samples and tubes across 9 racks
    • Efficient Barcode Reading: Streamlines sample identification, ensuring accurate tracking and processing
    • Extensive reagent storage with 40 reagent positions on 5 racks

    Broad assay portfolio

    • More than 100 assays for the detection of: Infectious Diseases, Fertility Hormones, Thyroid, Metabolism, Bone Marker, Tumor Marker, Allergy and Autoimmune
    • Compliance to quality requirements
    • Plug and run - most HUMAN assays preprogrammed

    High precision and enhanced safety features

    • Disposable carbon tips minimizes contamination risk, ensuring accurate and reliable results
    • Liquid level sensing automates accurate liquid detection, enhancing efficiency and reducing manual errors
    • Carry-over prevention utilizes advanced mechanisms to eliminate sample cross-contamination

    Intuitive and easy operation

    • Integrated pc and touchscreen for enhanced user experience simplifies operations
    • User-friendly graphical interface with a self-explanatory structure for effortless navigation
    • Real-time assay status and reagent allocation updates keeps users informed with permanent updates
    • Efficient time management tools, including a real-time-mode display and a processing time optimizer
    • Robust QC control program ensures the reliability and accuracy of results

    Techspecs

    Analyzer type

    2 plate fully automated ELISA analyzer

    Reagent system

    Open (HUMAN tests predefined)

    Reagent positions

    40 positions on 5 reagent racks

    Sample positions

    Up to 144 tubes

    Pipetting system

    300 µl and 1100 µl carbon tips

    Operation mode

    Prescheduled batch, continuous loading (plate batch)

    LIS

    Ethernet, bi-directional, ASTM & free definable
    protocol

    Dimensions (W x D x H)

    • Instrument without any components: 98 x 65 x 75 cm
    • Space required for routine use: 180 x 180 x 115 cm
    • Weight: 95 kg

    Enviromental conditions

    • Altitude: max. 2000 m above mean sea level
    • Operating: Temperature: 15...30 °C, Humidity: 30 - 80 % non condensing
    • Transport: Temperature: 5 – 50 °C, Humidity:10 - 85 % non-condensing

    Downloads

    Flyer

    Flyer Elisys Duo EN

    • Language:
      EN
    Flyer

    Flyer Elisys Duo ES

    • Language:
      ES
    Flyer

    Flyer Elisys Duo FR

    • Language:
      FR
    Flyer

    Flyer ELISA Line EN

    • Language:
      EN
    Flyer

    Flyer ELISA Line ES

    • Language:
      ES
    Flyer

    Flyer ELISA Line FR

    • Language:
      FR
    Application Sheet

    Application sheet for CMV IGM

    Application sheet for CMV Igm REF51103 containing instructions on how to run the CMV Igm reagent on Elisys Duo instruments.

    • Version:
      R4
    • Language:
      EN
    Application Sheet

    Application sheet for fPSA

    Application sheet for fPSA REF 52035 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Version:
      001
    • Language:
      EN
    Application Sheet

    Application sheet for anti-HBc

    Application sheet for anti-HBc REF 51260 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Language:
      EN
    Application Sheet

    Application sheet for anti-HBS

    Application sheet for anti-HBS REF 51255 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Language:
      EN
    Application Sheet

    Application sheet for HSV IgM

    Application sheet for HSV IgM REF 51126 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Version:
      4
    • Language:
      EN
    Application Sheet

    Application sheet for Rubella IgG

    Application sheet for Rubella IgG REF 51208 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Version:
      006
    • Language:
      EN
    Application Sheet

    Application sheet for IMTEC-dsDNA-Antibodies

    Application sheet for IMTEC-dsDNA-Antibodies REF 59001 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Version:
      004
    • Language:
      EN
    Application Sheet

    Application sheet for IMTEC-ß2-Glycoprotein I-Antibodies IgG

    Application sheet for IMTEC-ß2-Glycoprotein I-Antibodies IgG REF ITC59150 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Version:
      4
    • Language:
      EN
    Application Sheet

    Application sheet for IMTEC-SmD1-Antibodies

    Application sheet for IMTEC-SmD1-Antibodies REF ITC60029 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Version:
      4
    • Language:
      EN
    Application Sheet

    Application sheet for IMTEC-TPO-Antibodies

    Application sheet for IMTEC-TPO-Antibodies REF ITC85020 containing instructions on how to run the reagent on Elisys Duo instruments.

    • Version:
      4
    • Language:
      EN

    Associated Products

    Quantitative determination of IgG antibodies to anti-mitochondrial antigen M2.
    Qualitative determination of anti-nuclear IgG antibodies.

    Internal function and cut-off control
    Quantitative determination of IgG / IgA / IgM antibodies to annexin V.
    Calibration:6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 25 U/ml
    Quantitative determination of IgG autoantibodies to complement C1q.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 20 U/ml
    Determination of antibodies to cardiolipin
    Quantitative / qualitative determination of IgG antibodies to cyclic citrullinated peptide.
    Calibration: 25 / 50 / 200 / 800 / 1600 U/ml Cut-off: 25 U/ml
    Quantitative determination of C3d containing circulating immune complexes of IgG
    Quantitative determination of complement activity.
    Qualitative determination of IgG or IgM antibodies to Cytomegalo Virus
    Remark: CMV IgG (PEI Calibration)
    Quantitative determination of IgG antibodies to double-stranded DNA.
    Calibration: Quantitative, 12.5 / 25 / 50 / 100 / 200 IU/ml Cut-off: 25 U/ml

    Need help finding instrument?

    We will gladly assist you in making the right decision to achieve your business goals

    Get a consultation
    Need help finding instrument?