Calibrators & Controls

Reagents

HUMAN's reagents provide high-quality and reliable solutions tailored to meet diverse laboratory needs. Our range includes multipurpose clinical chemistry assays for manual and automated testing, offering precision in the detection of enzymes, substrates/metabolites, proteins, electrolytes, and trace elements detection. Our products ensure long-term stability and high accuracy. Each reagent kit includes necessary calibrators and standards, facilitating ease of use. With a commitment to innovation, HUMAN ensures that laboratories receive efficient, cost-effective diagnostic solutions that enhance the accuracy and reliability of their results.

Clear all
  • Autoimmune DX
  • HbA1c Measurement

63 Items are shown

Quantitative determination of IgG antibodies to anti-mitochondrial antigen M2.
Qualitative determination of anti-nuclear IgG antibodies.

Internal function and cut-off control
Quantitative determination of IgG / IgA / IgM antibodies to annexin V.
Calibration:6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG autoantibodies to complement C1q.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 20 U/ml

Qualitative determination of rheumatoid arthritis antibodies Internal function and cut-off control

Determination of antibodies to cardiolipin
Quantitative / qualitative determination of IgG antibodies to cyclic citrullinated peptide.
Calibration: 25 / 50 / 200 / 800 / 1600 U/ml Cut-off: 25 U/ml
Quantitative determination of C3d containing circulating immune complexes of IgG
Quantitative determination of complement activity.
Quantitative determination of IgG antibodies to double-stranded DNA.
Calibration: Quantitative, 12.5 / 25 / 50 / 100 / 200 IU/ml Cut-off: 25 U/ml
Simultaneously qualitative determination of IgG antibodies to extractable nuclear antigens.
Cut-off control and cut-off calibrator
Qualtitative determination of IgG / IgA antibodies to gastro intestinal diseases.
Quantitative determination of IgG antibodies to glomerular basement membrane.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
The determination of HbA1c is performed for the long term control in diabetes mellitus. HbA1c values provide an indication of the average glucose levels over the preceding 4-8 weeks. A high HbA1c value indicates poor glycemic control. Long term therapy of the disease requires control of blood glucose levels to prevent the acute complications of ketosis and hyperglycemia. In addition, preventing effective control of blood glucose levels can minimize long term complications such as retinopathy, neuropathy, and cardiovascular disease.

Immunoassay for the direct photometric determination of HbA1c in whole blood with EDTA.

Latex slide test for non-diluted serum.

Quantitative / qualitative determination of IgG antibodies to Jo-1.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Qualitative determination of IgG antibodies to autoimmune liver diseases.
Internal function and cut-off control
Quantitative determination of IgG antibodies to liver-kidney microsomal antigen 1.
Quantitative determination of IgG antibodies to myeloperoxidase.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Qualitative determination of myositis IgG antibodies.

Internal function and cut-off control
Quantitative determination of IgG antibodies to nucleosomes.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG / IgA / IgM antibodies to phosphatidylethanolamine.
Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15 U/ml
Determination of antibodies to phosphatidylserine
Quantitative determination of IgG / IgM antibodies to phospholipids.
Calibration: 6 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15-25 U/ml
Quantitative determination of IgG antibodies to proteinase 3.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Quantitative determination of IgG / IgA / IgM antibodies to prothrombin.
Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 30 U/ml
Quantitative determination of IgG antibodies to RA33.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgM antibodies to rheumatoid factor.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 15 IU/ml
Determination of antibodies to ß2-Glycoprotein 1
Qualitative determination of antibodies to salmonella.
Quantitative / qualitative determination of IgG antibodies to Scl70.
Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SmD.
Calibration: 12.5 /25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-A/Ro.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-B/La.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Determination of antibodies to thyroglobulin
Quantitative determination of antibodies to thyroperoxidase.
Quantitative determination of Thyrotropin.
Quantitative / qualitative determination of IgG antibodies to U1-snRNP.

Calibration: 12.5/25/50/100/200 U/ml

Cut-off: 25 U/ml
Qualitative determination of vasculitis IgG antibodies.

Internal function and cut-off control

Need help finding instrument?

We will gladly assist you in making the right decision to achieve your business goals

Get a consultation