Calibrators & Controls

Reagents

HUMAN's reagents provide high-quality and reliable solutions tailored to meet diverse laboratory needs. Our range includes multipurpose clinical chemistry assays for manual and automated testing, offering precision in the detection of enzymes, substrates/metabolites, proteins, electrolytes, and trace elements detection. Our products ensure long-term stability and high accuracy. Each reagent kit includes necessary calibrators and standards, facilitating ease of use. With a commitment to innovation, HUMAN ensures that laboratories receive efficient, cost-effective diagnostic solutions that enhance the accuracy and reliability of their results.

Clear all
  • Autoimmune DX
  • Multi Parameter Monitoring

54 Items are shown

Quantitative determination of IgG antibodies to anti-mitochondrial antigen M2.
Qualitative determination of anti-nuclear IgG antibodies.

Internal function and cut-off control
Quantitative determination of IgG / IgA / IgM antibodies to annexin V.
Calibration:6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG autoantibodies to complement C1q.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 20 U/ml

Qualitative determination of rheumatoid arthritis antibodies Internal function and cut-off control

Determination of antibodies to cardiolipin
Quantitative / qualitative determination of IgG antibodies to cyclic citrullinated peptide.
Calibration: 25 / 50 / 200 / 800 / 1600 U/ml Cut-off: 25 U/ml
Total cholesterol (CHOL) measurements are used for diagnosis and therapy control of atherosclerotic coronary vascular disease and metabolic disorders such as dyslipidemia and liver diseases. The concentration of total cholesterol in serum or plasma is influenced by different factors like age, sex, diet and physical activity.

Colorimetric enzymatic test for the quantitative determination of total cholesterol in human serum and plasma.
Quantitative determination of C3d containing circulating immune complexes of IgG
Quantitative determination of complement activity.
Quantitative determination of IgG antibodies to double-stranded DNA.
Calibration: Quantitative, 12.5 / 25 / 50 / 100 / 200 IU/ml Cut-off: 25 U/ml
Simultaneously qualitative determination of IgG antibodies to extractable nuclear antigens.
Cut-off control and cut-off calibrator
Qualtitative determination of IgG / IgA antibodies to gastro intestinal diseases.
Quantitative determination of IgG antibodies to glomerular basement membrane.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Glucose (GLUC) measurements are used for diagnosis and therapy control of carbohydrate metabolism disorders. Elevated glucose values (hyperglycemia) are observed in the following discorders: diabetes mellitus, gestational diabetes and Addison's disease. Decreased glucose values (hypoglycemia) are observed in neonatal hypoglycemia, congenital enzyme defects, Reye's syndrome, hepatic dysfunction, insulinomas, insulin antibodies, alcohol ingestion, neoplasms, sepsis and chronic renal failure.

Latex slide test for non-diluted serum.

Quantitative / qualitative determination of IgG antibodies to Jo-1.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Qualitative determination of IgG antibodies to autoimmune liver diseases.
Internal function and cut-off control
Quantitative determination of IgG antibodies to liver-kidney microsomal antigen 1.
Quantitative determination of IgG antibodies to myeloperoxidase.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Qualitative determination of myositis IgG antibodies.

Internal function and cut-off control
Quantitative determination of IgG antibodies to nucleosomes.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG / IgA / IgM antibodies to phosphatidylethanolamine.
Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15 U/ml
Determination of antibodies to phosphatidylserine
Quantitative determination of IgG / IgM antibodies to phospholipids.
Calibration: 6 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15-25 U/ml
Quantitative determination of IgG antibodies to proteinase 3.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Quantitative determination of IgG / IgA / IgM antibodies to prothrombin.
Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 30 U/ml
Quantitative determination of IgG antibodies to RA33.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgM antibodies to rheumatoid factor.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 15 IU/ml
Determination of antibodies to ß2-Glycoprotein 1
Qualitative determination of antibodies to salmonella.
Quantitative / qualitative determination of IgG antibodies to Scl70.
Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SmD.
Calibration: 12.5 /25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-A/Ro.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-B/La.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Determination of antibodies to thyroglobulin
Quantitative determination of antibodies to thyroperoxidase.
Quantitative determination of Thyrotropin.
Quantitative / qualitative determination of IgG antibodies to U1-snRNP.

Calibration: 12.5/25/50/100/200 U/ml

Cut-off: 25 U/ml
Qualitative determination of vasculitis IgG antibodies.

Internal function and cut-off control

Need help finding instrument?

We will gladly assist you in making the right decision to achieve your business goals

Get a consultation
Need help finding instrument?