HUMAN's reagents provide high-quality and reliable solutions tailored to meet diverse laboratory needs. Our range includes multipurpose clinical chemistry assays for manual and automated testing, offering precision in the detection of enzymes, substrates/metabolites, proteins, electrolytes, and trace elements detection. Our products ensure long-term stability and high accuracy. Each reagent kit includes necessary calibrators and standards, facilitating ease of use. With a commitment to innovation, HUMAN ensures that laboratories receive efficient, cost-effective diagnostic solutions that enhance the accuracy and reliability of their results.

Clear all
  • Autoimmune DX
  • Rapid Screening Tests

61 Items are shown

Quantitative determination of IgG antibodies to anti-mitochondrial antigen M2.
Qualitative determination of anti-nuclear IgG antibodies.

Internal function and cut-off control
Quantitative determination of IgG / IgA / IgM antibodies to annexin V.
Calibration:6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG autoantibodies to complement C1q.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 20 U/ml

Qualitative determination of rheumatoid arthritis antibodies Internal function and cut-off control

Determination of antibodies to cardiolipin
Quantitative / qualitative determination of IgG antibodies to cyclic citrullinated peptide.
Calibration: 25 / 50 / 200 / 800 / 1600 U/ml Cut-off: 25 U/ml
Quantitative determination of C3d containing circulating immune complexes of IgG
Quantitative determination of complement activity.
Quantitative determination of IgG antibodies to double-stranded DNA.
Calibration: Quantitative, 12.5 / 25 / 50 / 100 / 200 IU/ml Cut-off: 25 U/ml
Simultaneously qualitative determination of IgG antibodies to extractable nuclear antigens.
Cut-off control and cut-off calibrator
Agglutination slide and tube test for qualitative and semi-quantitative determination of antibodies against
Salmonella typhi H, Salmonella typhi O, Salmonella paratyphi AH, Salmonella paratyphi AO,
Salmonella paratyphi BH, Salmonella paratyphi BO, Salmonella paratyphi CH, Salmonella paratyphi CO
Qualtitative determination of IgG / IgA antibodies to gastro intestinal diseases.
Quantitative determination of IgG antibodies to glomerular basement membrane.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml

Latex slide test for non-diluted serum.

Hemagglutination slide test for heterophilic antibodies associated with infectious mononucleosis.
Quantitative / qualitative determination of IgG antibodies to Jo-1.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Qualitative determination of IgG antibodies to autoimmune liver diseases.
Internal function and cut-off control
Quantitative determination of IgG antibodies to liver-kidney microsomal antigen 1.
Quantitative determination of IgG antibodies to myeloperoxidase.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Qualitative determination of myositis IgG antibodies.

Internal function and cut-off control
Quantitative determination of IgG antibodies to nucleosomes.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Immunochromatographic rapid test for the qualitative detection of faecal occult blood in human stool
Quantitative determination of IgG / IgA / IgM antibodies to phosphatidylethanolamine.
Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15 U/ml
Determination of antibodies to phosphatidylserine
Quantitative determination of IgG / IgM antibodies to phospholipids.
Calibration: 6 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15-25 U/ml
Quantitative determination of IgG antibodies to proteinase 3.
Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Quantitative determination of IgG / IgA / IgM antibodies to prothrombin.
Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 30 U/ml
Quantitative determination of IgG antibodies to RA33.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgM antibodies to rheumatoid factor.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 15 IU/ml
Determination of antibodies to ß2-Glycoprotein 1
Qualitative determination of antibodies to salmonella.
Quantitative / qualitative determination of IgG antibodies to Scl70.
Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml
Latex slide test for serum.
Quantitative / qualitative determination of IgG antibodies to SmD.
Calibration: 12.5 /25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-A/Ro.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-B/La.
Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Determination of antibodies to thyroglobulin
Quantitative determination of antibodies to thyroperoxidase.
Quantitative determination of Thyrotropin.
Test for the triage of patients suspected for myocardial infarction in locations without access to particle-based chemiluminescent Troponin immunoassays.

Immunochromatographic 1-step test for cardiac troponin I (cTnI).

Detection limit: 0.5 ng/ml.
Quantitative / qualitative determination of IgG antibodies to U1-snRNP.

Calibration: 12.5/25/50/100/200 U/ml

Cut-off: 25 U/ml
Qualitative determination of vasculitis IgG antibodies.

Internal function and cut-off control