Calibrators & Controls

There occurred error (s)

    Reagents

    HUMAN's reagents provide high-quality and reliable solutions tailored to meet diverse laboratory needs. Our range includes multipurpose clinical chemistry assays for manual and automated testing, offering precision in the detection of enzymes, substrates/metabolites, proteins, electrolytes, and trace elements detection. Our products ensure long-term stability and high accuracy. Each reagent kit includes necessary calibrators and standards, facilitating ease of use. With a commitment to innovation, HUMAN ensures that laboratories receive efficient, cost-effective diagnostic solutions that enhance the accuracy and reliability of their results.

    Clear all
    • Hepatology
    • Rheumatology

    46 Items are shown

    Quantitative determination of IgG antibodies to anti-mitochondrial antigen M2.
    Qualitative determination of anti-nuclear IgG antibodies.

    Internal function and cut-off control
    Quantitative determination of IgG / IgA / IgM antibodies to annexin V.
    Calibration:6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 25 U/ml
    Quantitative determination of IgG autoantibodies to complement C1q.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 20 U/ml

    Qualitative determination of rheumatoid arthritis antibodies Internal function and cut-off control

    Determination of antibodies to cardiolipin
    Quantitative / qualitative determination of IgG antibodies to cyclic citrullinated peptide.
    Calibration: 25 / 50 / 200 / 800 / 1600 U/ml Cut-off: 25 U/ml
    Quantitative determination of C3d containing circulating immune complexes of IgG
    Quantitative determination of complement activity.
    Quantitative determination of IgG antibodies to double-stranded DNA.
    Calibration: Quantitative, 12.5 / 25 / 50 / 100 / 200 IU/ml Cut-off: 25 U/ml
    Simultaneously qualitative determination of IgG antibodies to extractable nuclear antigens.
    Cut-off control and cut-off calibrator
    Quantitative determination of IgG antibodies to glomerular basement membrane.
    Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
    Quantitative / qualitative determination of IgG antibodies to Jo-1.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
    Qualitative determination of IgG antibodies to autoimmune liver diseases.
    Internal function and cut-off control
    Quantitative determination of IgG antibodies to liver-kidney microsomal antigen 1.
    Quantitative determination of IgG antibodies to myeloperoxidase.
    Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
    Qualitative determination of myositis IgG antibodies.

    Internal function and cut-off control
    Quantitative determination of IgG antibodies to nucleosomes.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
    Quantitative determination of IgG / IgA / IgM antibodies to phosphatidylethanolamine.
    Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15 U/ml
    Determination of antibodies to phosphatidylserine
    Quantitative determination of IgG / IgM antibodies to phospholipids.
    Calibration: 6 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15-25 U/ml
    Quantitative determination of IgG antibodies to proteinase 3.
    Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
    Quantitative determination of IgG / IgA / IgM antibodies to prothrombin.
    Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 30 U/ml
    Quantitative determination of IgG antibodies to RA33.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
    Quantitative determination of IgM antibodies to rheumatoid factor.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 15 IU/ml
    Determination of antibodies to ß2-Glycoprotein 1
    Qualitative determination of antibodies to salmonella.
    Quantitative / qualitative determination of IgG antibodies to Scl70.
    Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml
    Quantitative / qualitative determination of IgG antibodies to SmD.
    Calibration: 12.5 /25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
    Quantitative / qualitative determination of IgG antibodies to SS-A/Ro.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
    Quantitative / qualitative determination of IgG antibodies to SS-B/La.
    Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
    Quantitative / qualitative determination of IgG antibodies to U1-snRNP.

    Calibration: 12.5/25/50/100/200 U/ml

    Cut-off: 25 U/ml
    Qualitative determination of vasculitis IgG antibodies.

    Internal function and cut-off control

    Need help finding instrument?

    We will gladly assist you in making the right decision to achieve your business goals

    Get a consultation